Energy efficient buildings sequence of analysis; building energy balance; weather data building energy use in the building energy use is described in figures. ITW/Buildex - 3/16' x 3-1/4' 410 Stainless Steel Flat Phillips Tapcon®. The Flat Head 410 Stainless Steel Tapcon® 3/16' x 3-1/4' comes packaged 100 pcs. Per box with one correctly sized bit. It can be used in brick, block, CMU, or concrete.
ITW/Buildex - 1/4' x 1-1/4' 410 Stainless Steel Hex Tapcon ® The 1/4' x 1-1/4' 410 Stainless Steel Hex Tapcon ® come packaged 100 pcs. Per box with one correctly sized bit.
They are designed specifically to be used in most common masonry base materials, such as concrete, brick or block. Each order is shipped the same day that it is received, and will arrive in 1 to 3 business days.
Bit size 3/16'. Minimum embedment 1'. Made in U.S.A. 410 stainless steel.
Hex head requires a 5/16' nut driver. Deemed acceptable for use with ACQ treated lumber. Can be closer to unsupported edge than expansion type anchors. Can be easily removed. No inserts required - just the screw. 1/4' inch refers to the diameter, 1-1/4' inch refers to the length measured from under the head. Orders over $25.00 will ship for free.
900 Type Male Diameter 1/4' Length 1-1/4' Material 410 Stainless Steel Silver Climaseal® Coated Environment Moist Box Qty 100 Minimum Spacing 4' Minimum Edge Distance 3' Maximum Fixture Thickness 1/4' Minimum Fixture Hole Diameter (In Place) 5/16' Minimum Fixture Hole Diameter (Hole Spotted) 5/16' Head Type Hex Washer Length Measurement Underneath head Driver Size 5/16' Brand Name ITW/Buildex. Applications The anchor is made from 410 Stainless Steel, and is Silver Climaseal ® Coated. This anchor is designed for use in Concrete, Block, and Brick. Environment The anchor is designed for use in a Moist environment. Head Style The anchor is a Hex Washer head and is designed to allow the head to sit on top of the surface of the item being attached. Hole Diameter/Bit Diameter The anchor requires a 3/16' hole to be drilled in the base material (Concrete, Block, and Brick).
The hole should be drilled with carbide tipped bit that meets ANSI standards and used in a hammer drill. Driver Required A 5/16' is required for driving the anchor into the base material. Diameter of Anchor The diameter of the anchor is 1/4'.
Length Anchor The length of the anchor is 1-1/4' Thread Length The length of the threads on the anchor is 1-1/4' in length. Packaging The anchor is packaged with 100 pieces per box and one (1) correct sized carbide bit. Minimum Embedment The minimum anchor embedment into the concrete is 1'. Therefore, the anchor must be installed so that a minimum of 1' of the anchor is embedded into the concrete. Depth of Hole The depth of the hole that is required for the anchor should be a minimum of 1/2' deeper than the anchor will penetrate the concrete. This will allow space for dust created during the installation process to fall, which will prevent the anchor from bottoming out in the hole before full penetration into the concrete.
Maximum Fixture Thickness The maximum fixture thickness or the maximum thickness of the material being fastened for a anchor is 1/4'. This will ensure that the minimum embedment of 1' will be met. Fixture Hole Diameter The hole in the fixture or material being fastened must be larger than the designated diameter of the anchor. The 1/4' diameter anchor requires the hole in the fixture to be 5/16'. Spacing between Anchors Each anchor must be spaced a minimum distance of 4' from each other when measured center to center.
Edge Distance It is very important not to install the anchor any closer than 3' from an unsupported edge of the concrete. Bolt Length When a bolt is used in conjunction with the anchor, the length of the bolt needed is determined by considering these factors:.
Flush With Concrete - when the anchor is set flush with the surface of the concrete, add the thickness of the material being fastened to the thread length of 1-1/4', and then add the space for any washers used. Below Surface of Concrete - add the depth below the surface of the concrete to the thickness of the material being fastened, then add the space for the washer, and, finally, add 1-1/4' for the thread engagement. Holding Values - Ultimate Load Values in 2000 PSI Concrete Anchor Size Minimum Embedment Pull-Out (lbs.) Shear (lbs.) 1/4' x 1-1/4' 1' 750 900. Installing a 1/4' x 1-1/4' 410 Stainless Steel Hex Tapcon ®.
Drill a 3/16' hole into the concrete using a carbide-tipped bit that meets ANSI Standards B212.15. Drill the hole a 1/2' deeper than the anchor will penetrate the concrete, making sure the minimum embedment requirements of 1' is met. The hole can be drilled while the fixture is in place. The minimum hole in the fixture for the 1/4' x 1-1/4' 410 Stainless Steel Hex Tapcon ® is 5/16'. Clean the hole with a wire brush, vacuum, compressed air, or a blow-out bulb. Insert the point of the 1/4' x 1-1/4' 410 Stainless Steel Hex Tapcon ® into the hole.
Make sure that the screw being installed will penetrate the base material a minimum of 1' but no deeper than 1-3/4'. Using a 5/16' nut driver hex driver for the anchor, turn the screw clockwise, applying slight pressure until the head of the screw is snug against the material being fastened. Always use proper personal protective equipment per manufacturer's and OSHA instructions.
These products are subject to quantities on hand or may require special ordering and are subject to minimum order quantities and longer lead times. Call Simpson Strong‑Tie for details (800) 999-5099. Coating/Material Screw Size Length (in.) Head Diameter (in.) Drive Type Head Type Thread Type TPI Point Type Packaging Qty.